Optically Clear Epoxy Passes ISO 10993-5 Certification for Cytotoxicity

May 3, 2021
EP30-4Med is a two part epoxy system with a fast set up time that cures at room temperature, or even more rapidly with a bit of heat. This low viscosity system meets the requirements of ISO 10993-5 testing and is therefore considered to be non-cytotoxic.

Master Bond EP30-4Med is a two part epoxy system with a fast set up time that cures at room temperature, or even more rapidly with a bit of heat. This low viscosity system meets the requirements of ISO 10993-5 testing and is therefore considered to be non-cytotoxic. It can be used for bonding, sealing, and small encapsulation applications. It can also be utilized as a coating, especially when optical clarity is needed.

EP30-4Med is designed to not only resist EtO sterilization, but also to withstand most detergents, disinfectants, bleaches and liquid sterilants. It is recommended for applications in medical device manufacturing for both disposable and reusable instruments. EP30-4Med has an easy to handle 2 to 1 mix ratio by weight and possesses a low viscosity of 1,000-3,000 cps for Part A and 20-100 cps for Part B. Mixing is effortless, especially with the use of a double barrel cartridge and static mixer. This epoxy has a refractive index of 1.55 and maintains good electrical insulation properties over time. Its volume resistivity is greater than 1015 ohm-cm. It forms strong bonds even in thin sections.

EP30-4Med is a relatively fast setting system, and in some cases, depending upon the application and the substrates, fixtures often can be removed in 15-25 minutes. Full cure can be achieved in about 24 hours at 75°F. The ideal cure schedule is around 1-2 hours at 75°F followed by 1-2 hours at 135-150°F. Upon cure, it exhibits a Shore D hardness of 75 to 85. The product is available in 1/2 pint kits, pint kits, quart kits, and gallon kits. Specialty packaging is available in gun dispensers.

Request a technical data sheet

Request a safety data sheet

Discuss your application

Learn More

Sponsored Recommendations

Request a free Micro 3D Printed sample part

April 11, 2024
The best way to understand the part quality we can achieve is by seeing it first-hand. Request a free 3D printed high-precision sample part.

Motion Scan and Data Collection Methods for Electro-Optic System Testing

April 10, 2024
Learn how different scanning patterns and approaches can be used in measuring an electro-optic sensor performance, by reading our whitepaper here!

Case Study: Medical Tube Laser Processing

March 28, 2024
To enhance their cardiovascular stent’s precision, optimize throughput and elevate part quality, a renowned manufacturer of medical products embarked on a mission to fabricate...

Melles Griot® XPLAN™ CCG Lens Series

March 19, 2024
IDEX Health & Science sets a new standard with our Melles Griot® XPLAN™ CCG Lens Series fluorescence microscope imaging systems. Access superior-quality optics with off-the-shelf...

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!