3D IMAGING/FLUORESCENCE MICROSCOPY: Microscopy technique generates 3D image as quickly as 2D

Jan. 21, 2014
Most microscopy approaches produce 3D imagery by scanning the depth of a sample, which is problematic for optically sensitive or fast-moving samples. But a simple, new technique correlates color and position information to enhance resolution in the third dimension, producing 3D images as quickly as 2D.

Most microscopy approaches produce 3D imagery by scanning the depth of a sample, which is problematic for optically sensitive or fast-moving samples. But a simple, new technique correlates color and position information to enhance resolution in the third dimension, producing 3D images as quickly as 2D.

Researchers at the Institute of Molecular Pathology (IMP) Vienna and the Vienna University of Technology (Austria) developed the technique. Kareem Elsayad, a researcher working with Katrin Heinze at IMP, designed a thin, biocompatible nanostructure consisting of a quartz microscope slide with a thin silver film and a dielectric layer. He then labeled a specimen with a fluorescent dye and placed it above the coated slide. "The measured emission spectrum of a fluorescent dye above this substrate depends on its distance from the substrate," he explained. "In other words, the position information of a collection of fluorophores is translated into color information, and this is what we were measuring in the end."

With their method, only one measurement is needed to determine the fluorophore distribution above the substrate, with a resolution down to 10 nm (in the direction away from the substrate). "Once the sample is placed on the substrate, which can be mass-produced, a confocal microscope with spectral detection is all that is needed," said Heinze.

Together with collaborators, Elsayad and Heinze used the method to study paxillin, a protein important for cell adhesion, in living cells. They also visualized the 3D dynamics of filopodia, small cell protrusions made of bundled actin-filaments that move very quickly and have a high turnover rate during cell migration.

Originally developed for a single fluorescent marker, the method could be adapted for more efficient DNA sequencing, among other applications.

1. K. Elsayad et al., Proc. Nat. Acad. Sci., doi:10.1073/pnas.1307222110 (2013).

About the Author

Barbara Gefvert | Editor-in-Chief, BioOptics World (2008-2020)

Barbara G. Gefvert has been a science and technology editor and writer since 1987, and served as editor in chief on multiple publications, including Sensors magazine for nearly a decade.

Sponsored Recommendations

Request a free Micro 3D Printed sample part

April 11, 2024
The best way to understand the part quality we can achieve is by seeing it first-hand. Request a free 3D printed high-precision sample part.

Motion Scan and Data Collection Methods for Electro-Optic System Testing

April 10, 2024
Learn how different scanning patterns and approaches can be used in measuring an electro-optic sensor performance, by reading our whitepaper here!

Case Study: Medical Tube Laser Processing

March 28, 2024
To enhance their cardiovascular stent’s precision, optimize throughput and elevate part quality, a renowned manufacturer of medical products embarked on a mission to fabricate...

Melles Griot® XPLAN™ CCG Lens Series

March 19, 2024
IDEX Health & Science sets a new standard with our Melles Griot® XPLAN™ CCG Lens Series fluorescence microscope imaging systems. Access superior-quality optics with off-the-shelf...

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!